| Application Note 005 Troubleshooting Guide for HID RFID Systems | |||||||||
|
|
Common Problems: |
Probable Cause(s) |
|
Tags don't read at all. |
|
|
Reading is slow or intermittent. |
|
|
Read range is short. |
|
The first step is to decide which one or combination of symptoms applies. Slow or intermittent reads may easily be mistaken for short reads if the tag is moved toward the reader quickly.
Generally, investigate results using the same tags with different readers or using different tags with the same readers.
To be able to perform all procedures in this document you will need the following. Some of them require no tools.
Noise is the most frustrating cause of malfunction because it often causes erratic results. It is also a common cause of system malfunction and should always be considered.
Some computer monitors or similar equipment and certain kinds of electrical machinery may produce rf noise that will interfere with the system. Power supplies of certain types, especially switching power supplies, may generate noise on the dc supply wires to the reader. Less frequently, host computer or panel connections may be a problem.
Noise may produce intermittent or slow reading, complete failure to read or short read range. It may produce inconsistent results, with symptoms appearing and disappearing over a long or short period.
Noise sources are generally of two types: radiating or conducting. Radiated noise is transmitted through the air. This is more common than conducted noise. Conducted noise comes into the reader via wires from the power supply or the host. Sometimes, switching power supplies generate enough noise to cause reader malfunction.
If you suspect that some nearby equipment is the cause, turn it off if possible and test the HID equipment. If that is not possible, try to separate the reader and the possible noise source. Various noise sources produce greater or lesser amounts of noise, so it is not possible to generalize about adequate separation. CRTs such as computer monitors will not usually affect a reader more than six feet away.
Radiating sources are often directional so that rotating them or the reader slowly through 90 degrees while attempting reads may producing convincing results. Not all sources are directional, so this is not a conclusive test if it fails.
The first check that should be made on the power supply is to verify that the dc voltage is correct to the reader when the reader is on. Note that noise levels adequate to disrupt reader operation can not be detected with a typical voltmeter, even on AC settings.
Power supply noise may be investigated by substituting a battery temporarily as the power source if a suitable battery is available. A "linear" power supply (laboratory style) of suitable voltage and current capacity may also be substituted.
When substituting a power source, first do so close to the reader. If that is successful, move the substitute power source physically near the intended power source so that noise pickup in power supply wires can be considered. If the reader works using the substitute supply in both locations, the system power supply is likely to be a source of excessive noise. If the reader works only with the substitute supply near the reader, power supply wiring is probably picking up noise. This is unusual, but if it occurs, try rerouting wires away from other equipment or using twisted, shielded wires with the shield grounded at the supply only.
Host computer or panel noise problems are easily isolated by disconnecting the wires to the host at the reader. The reader does not require a host to operate.
Tag problems will be characterized by consistent results at any given reader. Tag problems may produce short read range or failure to read. Tag problems are likely if:
Reader problems may exhibit many different symptoms. Incorrect mounting on metal or near closed metal loops may severely reduce range.
Readers are generally reliable and noise or tag problems should be investigated first unless it is easy to try a different reader.
The easiest way to isolate reader problems is to swap readers. Another is to cycle power to the reader and present a Continuous Read command card. If the reader will not read this card immediately after initialization (two indicator light flashes show correct initialization), it is not functioning correctly.
In many cases, the solution is clear once the source of a problem is isolated. This note is not intended to provide details for cases for which resolution is not clear. Contact your HID representative who will assist you in a final solution.
Prepared by J. Bradin